Liquid chromatography/mass spectrometry (LC/MS) has been applied to the analysis of triphenylboron, which has been produced as a substitute for organotin compounds, in water. Although commercial triphenylboron compounds are produced as pyridinyl complexes, the chemical form in water is supposed to be mainly triphenylboron after liberating pyridine. The triphenylborons were extracted from water with an EmporeTM C18 extraction disk under acidic condition, and the extracts were introduced directly into a liquid chromatograph-mass spectrometer equipped with a negative ion electrospray ionization interface. Identification of the compounds was performed with specific ions produced from the triphenylboron, and a quantitative analysis was carried out using the peak areas.The average recoveries from distilled water, seawater and river water at 0.30ng/ml were 92.3, 100 and 85.3%, respectively. A detection limit of 0.023ng/ml for triphenylboron was achieved.